Alexa Fluor® 647 anti-BAK1 Antibody

Pricing & Availability
Clone
W23097D (See other available formats)
Regulatory Status
RUO
Other Names
BCL2 antagonist/killer 1, BCL2L7, BAK, CDN1, Apoptosis regulator BAK, Bcl-2 homologous antagonist/killer
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
A.
W23097D_A647_BAK1_-IHC-P_092625
IHC staining with Alexa Fluor® 647 anti-BAK1 (clone W23097D) was performed on formalin-fixed paraffin embedded human skin tissue following antigen retrieval using Tris-EDTA pH 9.0 Antigen Retrieval Buffer (Cat. No. 422704). The tissue sections were incubated without (panel A) or with Alexa Fluor® 647 anti-BAK1 (clone W23097D) (panels B and C). Nuclei were counterstained with DAPI (Cat. No. 422801) (overlay in panels A and B). The images were captured on a Revvity Operetta CLS™ High Content Analysis System with a 20X objective. Scale bar: 100 µm
  • A.
W23097D_A647_BAK1_-IHC-P_092625
    IHC staining with Alexa Fluor® 647 anti-BAK1 (clone W23097D) was performed on formalin-fixed paraffin embedded human skin tissue following antigen retrieval using Tris-EDTA pH 9.0 Antigen Retrieval Buffer (Cat. No. 422704). The tissue sections were incubated without (panel A) or with Alexa Fluor® 647 anti-BAK1 (clone W23097D) (panels B and C). Nuclei were counterstained with DAPI (Cat. No. 422801) (overlay in panels A and B). The images were captured on a Revvity Operetta CLS™ High Content Analysis System with a 20X objective. Scale bar: 100 µm
  • B.
W23097D_A647_BAK1_ICFC_092625
    HAP1 WT cells (positive cell line, filled histogram) (Horizon Cat. No. C631) and HAP1 BAK1 Knockout cells (negative cell line, open histogram) (Horizon Cat. No. HZGHC005962c001) were fixed and permeabilized using True-Phos™ Perm Buffer (Cat. No. 425401) and intracellularly stained with Alexa Fluor® 647 anti-BAK1 (clone W23097D) or Alexa Fluor® 647 Rat IgG2a, κ Isotype Control (dashed histogram, representative of both the positive and negative cell lines) (Cat No. 400526).
Compare all formats See Alexa Fluor® 647 spectral data
Cat # Size Price Quantity Check Availability Save
693155 25 µg 148€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

BAK1 (Bcl-2 homologous antagonist/killer) is a crucial protein involved in regulating apoptosis, or programmed cell death, which is essential for maintaining cellular homeostasis. It functions as a pro-apoptotic factor, promoting cell death in response to various stress signals. BAK1 belongs to the BCL-2 family of proteins and plays a crucial role in the mitochondrial apoptotic process by promoting mitochondrial outer membrane permeabilization, which leads to the release of apoptogenic factors into the cytosol. BAK1 is regulated through interactions with other proteins, such as BCL-2 family members, which can either inhibit or promote its apoptotic activity. Dysregulation of BAK1 has been implicated in several diseases, thus, overexpression of BAK1 can contribute to neurodegenerative and autoimmune diseases by promoting excessive cell death. Conversely, inhibition of BAK1 is associated with the development of cancers, as it allows cells to evade apoptosis and continue proliferating.

Product Details
Quality Statement

This product was carefully developed for performance and specificity using the following products from Horizon Discovery, a Revvity company: HAP1 WT Cell Line (Horizon Cat No. Cat. No. C631) and HAP1 BAK1 Knockout cell line (Horizon Cat. No. HZGHC005962c001)

Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Recombinant Human BAK1 protein
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 647 under optimal conditions.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

IHC-P - Quality tested
ICFC - Verified

Recommended Usage

Each lot of this antibody is quality control tested by formalin-fixed paraffin-embedded immunohistochemical staining. For immunohistochemistry, a concentration range of 2.5 - 10.0 µg/mL is suggested. For flow cytometric staining, the suggested use of this reagent is ≤ 0.25 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 647 has a maximum emission of 668 nm when it is excited at 633 nm / 635 nm.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Red Laser (633 nm)
Additional Product Notes

For use of this antibody in intracellular flow cytometry (ICFC), we recommend fixation and permeabilization using True-Phos™ Perm Buffer (Cat. No. 425401).

For use of this antibody in immunohistochemistry on formalin-fixed paraffin-embedded tissues (IHC-P), we recommend antigen retrieval using either Citrate Buffer (Cat. No. 420902), or Tris-EDTA pH 9.0 Antigen Retrieval Buffer (Cat. No. 422704).

RRID
AB_3720605 (BioLegend Cat. No. 693155)

Antigen Details

Structure
BAK1 protein consists of 211 amino acids with a predicted molecular weight of 23 kDa.
Distribution

Mitochondrial outer membrane

Function
• Pro-apoptotic role: BAK1 promotes apoptosis by facilitating mitochondrial outer membrane permeabilization.
• Interaction with BCL-2 family: It interacts with other BCL-2 family proteins to regulate apoptosis.
• Release of apoptogenic factors: Upon activation, BAK1 helps release factors from the mitochondria that trigger the apoptotic cascade.
Interaction
• BCL-2 and BCL-XL: These anti-apoptotic proteins bind to BAK1, inhibiting its pro-apoptotic activity.
• BAX: BAK1 forms heterooligomers with BAX, another pro-apoptotic protein, to promote mitochondrial outer membrane permeabilization.
• p53: The tumor suppressor protein p53 interacts with BAK1 in response to cellular stress, enhancing its apoptotic function.
• MCL1: This anti-apoptotic protein also interacts with BAK1, regulating its activity.
• VDAC2: BAK1 interacts with the mitochondrial voltage-dependent anion channel 2, which is involved in the release of apoptogenic factors
Biology Area
Apoptosis/Tumor Suppressors/Cell Death, Cancer Biomarkers, Cell Biology, Mitochondrial Function, Neurodegeneration
Molecular Family
Mitochondrial Markers
Antigen References
  1. Dadsena S, et al. 2021. Biochem Biophys Acta Biomembr. 1863:183716
  2. Shalaby R, et al. 2020. Biomolecules. 10:1638
  3. Ramesh P, et al. 2020. Apoptosis. 25:305
  4. Pena-Blanco A, et al. 2018. FEBS J. 285:416
Regulation
• Protein interactions: BAK1 is regulated through its interactions with pro- and anti-apoptotic BCL-2 family members.
• Activation by stress signals: It remains inactive until activated by various cellular stress signals.
• Post-translational modifications: Phosphorylation and other modifications can influence BAK1's activity and stability.
Gene ID
578 View all products for this Gene ID
UniProt
View information about BAK1 on UniProt.org

Related FAQs

There are no FAQs for this product.

Other Formats

View All BAK1 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-BAK1 W23097D WB,IHC-P,ICC,ICFC,KO/KD-WB
Alexa Fluor® 488 anti-BAK1 Antibody W23097D ICFC
Alexa Fluor® 647 anti-BAK1 W23097D IHC-P,ICC
Go To Top Version: 1    Revision Date: 09/26/2025

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account